一是電(dian)(dian)源(yuan)方(fang)面的原(yuan)因:電(dian)(dian)壓偏高或偏低,在特定(ding)負載下,若(ruo)電(dian)(dian)壓變動(dong)范圍應在額定(ding)值的+10%到-5%之外會造成(cheng)電(dian)(dian)動(dong)機過(guo)熱(re);電(dian)(dian)源(yuan)三相電(dian)(dian)壓不對稱,電(dian)(dian)源(yuan)三相電(dian)(dian)電(dian)(dian)壓相間不平(ping)衡度超過(guo)5%,會引(yin)繞組過(guo)熱(re);缺相運行,經驗表明農用電(dian)(dian)動(dong)機被燒毀85%以上是由于缺相運行造成(cheng)的,應對電(dian)(dian)動(dong)機安(an)裝缺相保護裝置。
二是水泵方(fang)面的(de)原因:選用動(dong)力不配套(tao),小馬拉大車,電(dian)動(dong)機長時間過載運行,使電(dian)動(dong)機溫度過高(gao);啟(qi)動(dong)過于頻繁、定(ding)額為短時或斷續(xu)工作制的(de)電(dian)動(dong)機連續(xu)工作。應限制啟(qi)動(dong)次數(shu),正(zheng)確選用熱保護,按電(dian)動(dong)機上標定(ding)的(de)定(ding)額使用。
三是(shi)電(dian)動(dong)(dong)機本身的原(yuan)因:接法錯誤,將△形誤接成Y形,使電(dian)動(dong)(dong)機的溫度(du)迅(xun)(xun)速(su)升高;定子(zi)繞組有(you)相間短路、匝(za)間短路或局(ju)部接地,輕時(shi)電(dian)動(dong)(dong)機局(ju)部過熱(re),嚴重(zhong)時(shi)絕緣(yuan)燒壞;鼠(shu)籠轉子(zi)斷條或存在缺陷,電(dian)動(dong)(dong)機運(yun)行1到2小(xiao)時(shi),鐵(tie)芯溫度(du)迅(xun)(xun)速(su)上升;通(tong)風(feng)系統發生(sheng)故障,應檢查風(feng)扇是(shi)否(fou)損(sun)壞,旋轉方向是(shi)否(fou)正確(que),通(tong)風(feng)孔道是(shi)否(fou)堵(du)塞;軸承磨損(sun)、轉子(zi)偏心(xin)掃膛使定轉子(zi)鐵(tie)心(xin)相擦發出(chu)金屬撞擊(ji)聲(sheng),鐵(tie)芯溫度(du)迅(xun)(xun)速(su)上升,嚴重(zhong)時(shi)電(dian)動(dong)(dong)機冒煙,甚到線圈(quan)燒毀(hui)。
四是工作環境(jing)(jing)方面的(de)原因(yin):電(dian)(dian)動機繞組受潮(chao)或(huo)灰塵(chen)、油污等附著在(zai)繞組上,導致絕(jue)緣降低。應測量電(dian)(dian)動機的(de)絕(jue)緣電(dian)(dian)阻并進(jin)行清掃、干(gan)燥處(chu)理(li);環境(jing)(jing)溫(wen)(wen)度(du)過高(gao)(gao)。當環境(jing)(jing)溫(wen)(wen)度(du)超過35℃時,進(jin)風溫(wen)(wen)度(du)高(gao)(gao),會使電(dian)(dian)動機的(de)溫(wen)(wen)度(du)過高(gao)(gao),應設法(fa)豐富其工作環境(jing)(jing)。如(ru)搭棚遮陽等。因(yin)電(dian)(dian)方面的(de)原因(yin)發生故障,應請獲得專業資格證(zheng)書的(de)電(dian)(dian)工維修(xiu),一知半(ban)解的(de)人不可盲目維修(xiu),防止人身傷(shang)害事故的(de)發生。
致力于泵閥生產研發 創造更多無限可能該(gai)網站(zhan)所(suo)有產品(pin)圖(tu)及宣傳圖(tu)片屬于高適所(suo)有,任何個人和組(zu)織不得(de)使(shi)用(yong)(yong),盜用(yong)(yong)必究。
微信關注
全國服務熱線
400-8783-167
地址:上海(hai)市奉賢區陳橋路1887號1幢3層F139室